PT. REJEKI PRIMA STEEL
PT. REJEKI PRIMA STEEL
Jl. P. Jayakarta Blok 26 No B5 Jakarta 10730, Jakarta
M , YUNUS
Hp : 0878 8100 8840
Fax. : 021 6257736
Pin BB : 298954E4
e-mail : yunusprimasteel@gmail.com
PIPA SPINDO
Pipa sch40 memenuhi standard ASTM A53 Grade A
Info Produk
SPINDO adalah pabrik pipa besi ERW yang ada di Indonesia. Berikut adalah daftar pipe produksi SPINDO: - Pipa gas/ Hitam SPINDO Med A - Pipa gas/ Hitam SPINDO A53 Grade A Sch40 - Pipa gas/ Hitam SPINDO Med B - Pipa gas/ Hitam SPINDO BSA A - Pipa gas/ Hitam SPINDO KSZ - Pipa gas/ Hitam SPINDO WSZ - Pipa gas/ Hitam SPINDO SD - Pipe Galvanis ( GIP) / Pipa Air SPINDO Med A - Pipe Galvanis ( GIP) / Pipa Air SPINDO A53 Grade A Sch40 - Pipe Galvanis ( GIP) / Pipa Air SPINDO Med B - Pipe Galvanis ( GIP) / Pipa Air SPINDO BSA A - Pipe Galvanis ( GIP) / Pipa Air SPINDO KSZ - Pipe Galvanis ( GIP) / Pipa Air SPINDO WSZ - Pipe Galvanis ( GIP) / Pipa Air SPINDO SD Semua pipa diatas adalah tipe welded Pipa gas/ hitam SPINDO Med A memenuhi standard SNI 0039: 2010. Pipa sch40 memenuhi standard ASTM A53 Grade A
PT. REJEKI PRIMA STEEL
Jl. P. Jayakarta Blok 26 No B5 Jakarta 10730, Jakarta
M , YUNUS
Hp : 0878 8100 8840
Fax. : 021 6257736
Pin BB : 298954E4
e-mail : yunusprimasteel@gmail.com
Pipa Black Steel sch40 memenuhi standard ASTM A53 Grade A
Pipe Galvanis ( GIP) / Pipa Air SPINDO,Medium,sch 40
VICTAULIC FIRE LOCK
PT. REJEKI PRIMA STEEL
Jl. P. Jayakarta Blok 26 No B5 Jakarta 10730, Jakarta
M , YUNUS
Hp : 0878 8100 8840
Fax. : 021 6257736
Pin BB : 298954E4
e-mail : yunusprimasteel@gmail.com
Pipa Spindo
PT. REJEKI PRIMA STEEL
PT. REJEKI PRIMA STEEL
* Pipa Spindo
*PT.Steel Pipa Industry of Indonesia (SPINDO) merupakan perusahaan dalam negeri yang berpengalaman dalam memproduksi pipa baja/tabung dalam bentuk besi hitam dan galvanis dan berbagai produk terkait lainnya,serta selalu inovatif dalam rangka memenuhi kebutuhan-kebutuhan spesifik para konsumennya.
Didirikan pada tahun 1971 memperkerjakan 1000 tenaga kerja y yang terbagi di lima unit pabrik.Jaminan mutu produk telah bersertifikat internasional ISO 9002 dan API 5L,sesuai dengan persyaratan mutu internasional PT.SPINDO memenuhi standar ASTM,BS,JIS,ISO,API,AS, dan SNI.Jaminan pruduk
Info Produk
SPINDO adalah pabrik pipa besi ERW yang ada di Indonesia. Berikut adalah daftar pipe produksi SPINDO:
- Pipa gas/ Hitam SPINDO Med A
- Pipa gas/ Hitam SPINDO A53 Grade A Sch40
- Pipa gas/ Hitam SPINDO Med B
- Pipa gas/ Hitam SPINDO BSA A
- Pipa gas/ Hitam SPINDO KSZ
- Pipa gas/ Hitam SPINDO WSZ
- Pipa gas/ Hitam SPINDO SD
- Pipe Galvanis ( GIP) / Pipa Air SPINDO Med A
- Pipe Galvanis ( GIP) / Pipa Air SPINDO A53 Grade A Sch40
- Pipe Galvanis ( GIP) / Pipa Air SPINDO Med B
- Pipe Galvanis ( GIP) / Pipa Air SPINDO BSA A
- Pipe Galvanis ( GIP) / Pipa Air SPINDO KSZ
- Pipe Galvanis ( GIP) / Pipa Air SPINDO WSZ
- Pipe Galvanis ( GIP) / Pipa Air SPINDO SD
Semua pipa diatas adalah tipe welded
Pipa gas/ hitam SPINDO Med A memenuhi standard SNI 0039: 2010.
Pipa sch40 memenuhi standard ASTM A53 Grade A
Grade A: Yield 30, 000 ( 205MPa) psi. Min Tensile: 48, 000 ( 330MPa) min
Grade B: Yield 35, 000 ( 240MPa) psi. Min Tensile: 60, 000 ( 415MPa) min
PT. REJEKI PRIMA STEEL
Jl. P. Jayakarta Blok 26 No B5 Jakarta 10730, Jakarta
M , YUNUS
Hp : 0878 8100 8840
Fax. : 021 6257736
Pin BB : 298954E4
e-mail : yunusprimasteel@gmail.com
PIPA SPINDO
Pipa Black steel Sch 40 Dan Medium SNI
MOTORIZED BUTTERFLY VALVE
HONEYWELL, MANUAL BUTTERFLY VALVE
Product Specifications
Valve Type : Manual Butterfly Valve
Body Pattern : Two-Way, Straight-through
Connection Type : Wafer ISO7005-2
Pipe Size (Inch) : 2"
Pipe Size (DN) : DN 50
Flow Capacity (Kvs) : 109
Pressure Ratings (kPa) : 1600
Leakage Rate (%) : No Visible Leakage
Fluid Temperature Range (C) : -10 to 90
Fluid Temperature Range (F) : 14 to 194
Material (Body) : GG25
Material (Stem) : SS 416
Material (Plug/Ball/Disc) : Epoxy Coated Ductile Irone GGG40
Weight (kg) : 7.7
PT. REJEKI PRIMA STEEL
Jl. P. Jayakarta Blok 26 No B5 Jakarta 10730, Jakarta
M , YUNUS
Hp : 0878 8100 8840
Fax. : 021 6257736
Pin BB : 298954E4
e-mail : yunusprimasteel@gmail.com
|
Valve Type : Balancing Valve
Body Pattern : Two-Way
Controlled Medium : Water
Flow Capacity (Cv) : 86.82 - 2590.74
Flow Capacity (Kvs) : 74.4 -2220
Pipe Size (Inch) : 2 1/2" - 14"
Pipe Size (DN) : DN65 - DN350
Connection Type : BS4504 PN16 or ANSI B16.1 Class 125
Maximum Operating Pressure (Psi) : 240Maximum Operating Pressure (kPa) : 1654.752
Materials (Body) : Bronze
Material (Seat) : EPDM O-ring seals on Noryl piston
Material (Stem) : Stainless Steel
Materials (Plug/Ball/Disc) : Carbon Steel
Used With : HVAC invariable flowrate hydronic system
Materials (Cartridge) : Brass, chrome plated
Pressure Reducing Valve, savety valve ,ex Watts
PRESSURE REDUCING VALVE (PRV)
Watts Series 115 Pressure Reducing Valves (PRV)
• Limits downstream pressure to pre-set maximum
• Maintains constant maximum outlet pressures• Typically used in commercial and industrial installations where downstream devices require protection from fluctuating supply pressure
• Automatically reduces higher inlet pressure to a constant outlet pressure
• Unaffected by changing flow rates or inlet pressures
• Precise alignment and stable throttling
• Synthetic rubber/nylon diaphragm creates variable volume chamber
• Drip-tight, dynamic quad seal
• Fused epoxy coated, cast iron construction for maximum service life
• Please specify required kPa setting at time of order
WATTS AUTOMATIC CONTROL VALVE
Automatic Control Valves
Performance is standard: The
design and innovative features incorporated into every Watts Automatic
Control Valve means consistent,dependable, high performance, positive
control andlong life.Efficient design: The main valve, globe or angle pattern, is diaphragm actuated, hydraulically operated. It consists of only fourmajor components.
Drip tight seal: Watts ACV leads the automatic valve industry by beingthe first to incorporate the dynamic quad seal. The seat,retained on 3 1/2+ sides, provides positive closurewhile eliminating the need to “bite” into the seal,
Fused epoxy prolongs life: This coating is applied under rigorous preparation andapplication standards. It is non-porous, improving theflow coefficiency of the valve and effectively sealing thecasting from interaction with the controlled liquid. Thecoating also protects the valve from environmentalattack.
Right place, Right time: Watts ACV is committed to providing you with correctfunction and material to meet your applicationrequirements and prides itself with accurate, calculateddelivery schedules.
PT. REJEKI PRIMA STEEL
Jl. P. Jayakarta Blok 26 No B5 Jakarta 10730, Jakarta
M , YUNUS
Hp : 0878 8100 8840
Fax. : 021 6257736
Pin BB : 298954E4
e-mail : yunusprimasteel@gmail.com
PRESSURE RELIEF VALVE
WATTS, PRESSURE RELIEF VALVE, M116
Description:
The WATTS ACV Pressure Relief, Sustaining or Backpressure Control Valve
is designed to permit flow when upstream pressure is above the
adjustable setpoint of the control pilot, and throttle toward closed
when upstream pressure falls below the adjustable setpoint.
When the valve is installed "off the main line" on the branch of a tee, it serves as a Pressure Relief Control Valve. It is normally closed, and quickly opens when upstream pressure exceeds the pilot setting, relieving excess pressure.
When valve installed "in line" connecting two distribution zones, the valve acts as a Pressure Sustaining Control Valve. When pressure in the upstream zone falls below the pilot setting, the valve modulates toward a closed position, sustaining pressure in the upstream zone.
When the valve is installed "in line" on the discharge of a pump, it acts as Backpressure Control Valve. When pump discharge pressure falls below the pilot setting, the valve modulates toward a closed position, increasing backpressure against the pump.
When the valve is installed "off the main line" on the branch of a tee, it serves as a Pressure Relief Control Valve. It is normally closed, and quickly opens when upstream pressure exceeds the pilot setting, relieving excess pressure.
When valve installed "in line" connecting two distribution zones, the valve acts as a Pressure Sustaining Control Valve. When pressure in the upstream zone falls below the pilot setting, the valve modulates toward a closed position, sustaining pressure in the upstream zone.
When the valve is installed "in line" on the discharge of a pump, it acts as Backpressure Control Valve. When pump discharge pressure falls below the pilot setting, the valve modulates toward a closed position, increasing backpressure against the pump.
Langganan:
Entri (Atom)
Tidak ada komentar:
Posting Komentar